数量阶梯 | 香港交货 | 国内含税 |
+xxxx | $xxxx | ¥xxxx |
查看当月历史价格
查看今年历史价格
HAC 400-S产品简介:
ICGOO电子元器件商城为您提供HAC 400-S由LEM设计生产,在icgoo商城现货销售,并且可以通过原厂、代理商等渠道进行代购。 HAC 400-S价格参考。LEMHAC 400-S封装/规格:电流变送器, 电流传感器 400A 1 通道 霍尔效应,开环 双向 模块。您可以下载HAC 400-S参考资料、Datasheet数据手册功能说明书,资料中有HAC 400-S 详细功能的应用电路图电压和使用方法及教程。
参数 | 数值 |
产品目录 | |
描述 | SENSOR CURR 400A 2500V MOD |
产品分类 | |
品牌 | LEM USA Inc |
数据手册 | |
产品图片 | |
产品型号 | HAC 400-S |
rohs | 无铅 / 符合限制有害物质指令(RoHS)规范要求 |
产品系列 | HAC |
传感器类型 | 霍尔效应, 开环 |
其它名称 | 398-1108 |
包装 | 散装 |
响应时间 | 7µs |
安装类型 | 面板安装 |
封装/外壳 | 模块 |
工作温度 | -10°C ~ 80°C |
极化 | 双向 |
标准包装 | 15 |
灵敏度 | - |
用于测量 | AC/DC |
电压-电源 | ±15V |
电流-检测 | 400A |
电流-电源(最大值) | 25mA |
精度 | ±1% |
线性度 | ±1% |
输出 | 比率, 电压 |
通道数 | 1 |
频率 | DC ~ 50kHz |
Current Transducer HAC 100 ... 800-S I = 100 ... 800 A P N For the electronic measurement of currents: DC, AC, pulsed..., with galvanic separation between the primary circuit and the secondary circuit. Electrical data Features Type Primary nominal Primary current, ● Hall effect measuring principle RMS current measuring range ● Insulating plastic case recognized I (A) I (A) P N P M according to UL 94-V0. HAC 100-S 100 ±300 HAC 200-S 200 ±600 Advantages HAC 300-S 300 ±900 ● Low insertion losses HAC 400-S 400 ±1200 ● Easy installation HAC 500-S 500 ±1500 U HAC 600-S 600 ±1800 I ● Low power consumption C P ● Small size and space saving HAC 800-S 800 ±1800 ● Only one design for wide current U Supply voltage (±5 %) 1) ±15 V C ratings range I Current consumption HAC 100 ... 300-S < ±18 mA R C ● High immunity to Mexternal HAC 400 ... 800-S < ±25 mA interference. R Insulation resistance @ 500 V DC > 1000 MΩ dCl UIoNuSt Outpudt Cvpoltage (Analog) @ ±IP N, RL = 10 kΩ, TA = 25 °C ±4 V Applications UC R Output internal resistance 100 Ω out R Load resistance > 10 kΩ ● AC variable speed drives and L servo motor drives Accuracy - Dynamic performance data ● Static converters for DC motor drivers ε Error @ I , T = 25 °C (excluding offset) < ±1 % of I P N A P N ● Battery supplied applications ε Linearity error (0 ... ±I ) < ±1 % of I L P N P N ● Uninterruptible Power Supplies U Electrical offset voltage @ T = 25 °C < ±30 mV O E A (UPS) U Hysteresis offset voltage @ I = 0, O H P ● Switched Mode Power Supplies after an excursion of 1 × I < ±35 mV P N (SMPS) TCU Temperature coefficient of U < ±1 mV/K O E O E ● Power suppliers for welding TCU Temperature coefficient of U (% of reading) < ±0.1 %/K out out applications. t Delay time to 90 % of I < 7 µs D 90 P N BW Frequency bandwidth (−3 dB) 2) DC ... 50 kHz Application domain General data ● Industrial. T Ambient operating temperature −10 ... +80 °C A T Ambient storage temperature −15 ... +85 °C S m Mass 70 g Standards EN 50178: 1997 3) UL 508: 2010 Notes: 1) Operating at ±12 V < U < ±15 V will reduce the measuring range C 2) Derating is needed to avoid excessive core heating at high frequency 3) For HAC 100 ... 300-S, regarding compliance towards IEC 61000-4-3 (EN61000-6-2 (2005)): Variation of the offset between 250 to 400 MHz. N° 74.05.34.000.0, N° 74.05.44.000.0, N° 74.05.46.000.0, N° 74.05.48.000.0, N° 74.05.50.000.0, N° 74.05.52.000.0, N° 74.05.56.000.0 Page 1/4 29April2019/version 13 LEM reserves the right to carry out modifications on its transducers, LEM International SA in order to improve them, without prior notice Chemin des Aulx 8 1228 PLAN-LES-OUATES Switzerland www.lem.com
UL 508:Ratings and assumptions of certification HAC 100 ... 800-S File # E189713 Volume: 2 Section: 1 Standards ● CSA C22.2 NO. 14 - 10 INDUSTRIAL CONTROL EQUIPMENT - Edition 11 - Revision Date 2011/08/01 ● UL 508 STANDARD FOR INDUSTRIAL CONTROL EQUIPMENT - Edition 17 - Revision Date 2010/04/15. Parameter Symbol Unit Value Primary involved potential V AC/DC 600 Ambient operating temperature T °C 80 A According to series primary Primary current I A P currents Supply voltage U V DC 0 to ±15 C Output voltage U V 0 to 4 out Conditions of acceptability When installed in the end-use equiment, consideration shall be given to the following: 1 - These devices must be mounted in a suitable end-use enclosure. 2 - The terminals have not been evaluated for field wiring. 3 - Low voltage circuits are intended to be powered by a circuit derived from an isolating source (such as a transformer,optical isolator, limiting impedance or electro-mechanical relay) and having no direct connection back to the primary circuit (other than through the grounding means). 4 - Base on results of temperature tests, int he end use application, a maximum of 100 °C cannot be exceeded at soldering point between primary coil pin and soldering point of on the primary bus bar (corrected to the appropriate evaludated max. surrounding air). Marking Only those products bearing the UL or UR Mark should be considered to be Listed or Recognized and covered under UL’s Follow-Up Service.Always look for the Mark on the product. Page 2/4 29April2019/version 13 LEM reserves the right to carry out modifications on its transducers, LEM International SA in order to improve them, without prior notice Chemin des Aulx 8 1228 PLAN-LES-OUATES Switzerland www.lem.com
Current Transducer HAC 100 ... 800-S Insulation coordination U RMS voltage for AC insulation test, 50 Hz/1 min 2.5 1) kV d Min d Creepage distance 5 mm Cp d Clearance 5 mm CI CTI Comparative tracking index (group IIIa) 220 Note: 1) Between primary and secondary. Applications examples According to EN 50178 and IEC 61010-1 standards and following conditions: ● Over voltage category OV 3 ● Pollution degree PD2 ● Non-uniform field EN 50178 IEC 61010-1 d , d , U Rated insulation voltage Nominal voltage Cp CI Ni Basic insulation 500 V Cat III 500 V RMS Reinforced insulation 150 V Cat III 250 V RMS Safety This transducer must be used in limited-energy secondary circuits according to IEC 61010-1. This transducer must be used in electric/electronic equipment with respect to applicable standards and safety requirements in accordance with the manufacturer’s operating instructions. Caution, risk of electrical shock When operating the transducer, certain parts of the module can carry hazardous voltage (eg. primary busbar, power supply). Ignoring this warning can lead to injury and/or cause serious damage. This transducer is a build-in device, whose conducting parts must be inaccessible after installation. A protective housing or additional shield could be used. Main supply must be able to be disconnected. Page 3/4 29April2019/version 13 LEM reserves the right to carry out modifications on its transducers, LEM International SA in order to improve them, without prior notice Chemin des Aulx 8 1228 PLAN-LES-OUATES Switzerland www.lem.com
Dimensions HAC 100 ... 800-S (in mm) 第一视角 第三视角 第一视角 第三视角 Connection U U I C I C P P U I C RM P RM d d U d d U Cl Cp C Cl Cp C R M d d U Cl Cp C Mechanical characteristics Remarks ● General tolerance ±0.5 mm ● U is positive when I flows in the direction of the arrow. out P ● Transducer fastening 1 hole 4.5 ● Temperature of the primary conductor should not exceed ⌀ 1 M4 steel screw 100 °C. Recommended fastening torque 1.2 N·m ● Installation of the transducer must be done unless ● Primary through-hole 24 × 16 mm otherwise specified on the datasheet, according to LEM ● Connection of secondary Molex 5045-04AG Transducer Generic Mounting Rules. Please refer to LEM document N°ANE120504 available on our Web site: https://www.lem.com/en/file/3137/download/. ● Dynamic performances (di/dt and delay time) are best with a single bar completely filling the primary hole. Page 4/4 29April2019/version 13 LEM reserves the right to carry out modifications on its transducers, LEM International SA in order to improve them, without prior notice Chemin des Aulx 8 1228 PLAN-LES-OUATES Switzerland www.lem.com